TC 401 Traffic Intersection Control Power Supply

90-264 VAC Input / 12 and 48 VDC 400 Watts Output

FEATURES:

  • Universal 90-264 VAC full range voltage input
  • Wide operating temperature: -25°C to +65°C
  • Power Factor ≥0.95
  • Input anti-surge and anti lightning strike design
  • Output over-voltage, output over-current, output short-circuit and over-temperature protection
  • Current sharing and parallel operation
  • Flame-retardant and moisture-proof design
  • Low leakage current: ≤0.75mA
  • High Efficiency / High Reliability
  • For use in existing and new configurations
  • Custom Configurations Available
OUTPUT VOLTAGE(S) 12V @ 0.5A, 48V @ 8.3A
POWER RATING: 400 WATTS
SKU: TC401

Description

Jasper Electronics Model TC401-M1558G Power Supply has a wide universal input voltage range of 90-264VAC, dual outputs at 12 and 48 VDC, and overall high power density. This unit features output short-circuit protection, over-current protection, over-voltage protection, over-temperature protection, and parallel current sharing. Please see below for full specifications.

ModelVIN Range
(VAC)
Vout
(VDC)
IOut
(A)
Rated Power
(W)
Dimensions
(LxWxH)
TC401-M1558G90-264V48V0-8.3A400W127 x 82 x 41 mm
12V0-0.5A
ENVIRONMENTAL
ParameterMinTypMaxUnitRemark
Operating Temperature-2565°C
Storage Temperature-4085°C
Relative Humidity2095%Non-condensing
Cooling MethodFactory recommends conduction cooling via heatsink or baseplate for full load operation. If the output is derated below 70%, convection cooling is acceptable
INPUT CHARACTERISTICS
ParameterMinTypMaxUnitRemark
Input Voltage Range90100/240264VAC
Input Current5AInput at 90VAC
Inrush Current1440A264VAC input
Input Frequency Range475063Hz
Power Factor0.95220VAC input, rated load
OUTPUT CHARACTERISTICS
ParameterMinTypMaxUnitRemark
Output Voltage48VVDCDefault set at 48V
12VVDC12V - supply for external fan
Output Current08.3A48V
00.5A12V
Output Power400W
Efficiency9094.5%220VAC input, 48V Full Load
Ripple & Noise (Peak-Peak)480m Vp-pRated input and load range. output is decoupled by a high frequency 0.1 μF cap and one 1 0μF electrolytic capacitors. Bandwidth set at 20MHz
Load Regulation±3%
Line Regulation±2%
Temperature Coefficient±0.02%/°C
On / Off Overshoot±10%
Dynamic Response Overshoot±5%25%~50%~25%ElJZ 50%~75%~50% load change
Dynamic Response
Recovery Time
200ūS
Start-up Time1S220VAC input, full load
Current Imbalance10%Parallel operation
PROTECTION
ParameterMinTypMaxUnitRemark
Over Voltage56V48V, half load
Over Current915A220VAC Input, 48V, hiccup
Short CircuitCan withstand permanent short
Over TemperatureSelf recover when temperature within set limit

Model TC401 Datasheet