TC 206L NYSDOT Power Supply
AC Input, 120W Single DC Output
FEATURES:
- For use in NYSDOT 332 and 336 cabinets
- For use in Traffic Intersection Control Systems
- For use in LED Road Signs
- High Efficiency / High Reliability
- For use in existing and new configurations
- Custom Configurations Available
- Description
- Specifications
- Data Sheets
Description
Jasper Electronics Model TC206L-NY component 206L Power Supply NYSDOT is a switching power supply capable of delivering up to 120 Watts of DC power through a single, regulated +24V DC output. It provides full output regulation across changes in AC Line voltage and output load over the full operating temperature range of -34°C to +74°C. Power Factor Correction is provided, reducing peak AC Line input current and the associated stress on wiring. This model has a functional AC input range of 80V AC to 270V AC input and 47 to 63Hz. Model TC206L-NY is designed to be rack mounted in a TEES type PDA #2L, PDA #3L or PDA #4L assembly as commonly found in 332 or 336 style traffic signal control cabinets.
INPUT | |
Voltage/ Current Rating | AC 90-250V, 47-63Hz, 1.6A max, Single Phase |
TEES Minimum | AC 90-132V, 57-63Hz, 1.6A max |
Fusing | AC 3.15A, 250V delayed (slow-blow) action 5x20mm AG cartridge type external line fuse provided, operator accessible. Fuse IEC 60127-2/3 compliant |
Inrush Current | Soft start (~25ºC cold start) 30Apk @ AC 115V |
Power Factor | >0.98 line PFC typical at AC 115V, full load |
Efficiency | At AC 115V: >75% @ 1.0A; >84% @ 2.5A; >86% @ 5.0A |
OUTPUT | |
Voltage/Current (V/A) | V1 |
Model CM121-5-M1375G | 24.0V, 5.0A |
Total loading not to exceed 120 Watts at +165.2°F[+74ºC] | |
Output Voltage Setpoint | Factory preset within ±2.0% of nominal voltage |
Line Regulation | <±2.0% at the output connection over the full AC input range and 0 – 100% output loading |
Minimum Loading | None required |
Output Turn-on Delay | <200mSec from AC turn-on |
Over/ Under Shoot | None at turn-on or turn-off |
Stability | <±0.2% output drift after 20 minute warm-up |
Temperature Coefficient | <±0.02%/°C, 0° - 50°C, after 20 minute warm-up |
Dynamic Response | <±5.0% deviation with a 50% load change at a slew rate of 1A/μsec. Output recovers to within 5% in less than 300μsec |
Ripple and Noise (PARD) | 2.0V max peak-to-peak / 500mV RMS nominal at the output terminal with a 20MHz bandwidth limit. May be measured with a 0.1μF ceramic capacitor in parallel with a 22μF tantalum capacitor connected between the measured output and its return |
Over Voltage Protection (OVP) | Non-crowbar type from 27.6V to 32.4V |
Over Current/ Short Circuit Protection | Protected against overload from 6A to 8A and short-circuit faults. Automatic recovery when overload removed |
Over Temperature Protection | Internal temperature sensing. Causes output to shut down. Automatic recovery |
Output Transient Protection | Minimum 1400W voltage transient suppressor provided |
Output Fusing | AC 8.0A, 250V delayed (slow-blow) action 5x20mm AG cartridge type external fuse provided in the (+) output, operator accessible. Fuse IEC 60127-2/3 compliant |
SIGNALS, INDICATORS AND CONTROLS | |
AC Power Indicator | Front panel mounted, single-color LED. Red indicates AC power ON. Off indicates an input fault |
DC Power Indicator | Front panel mounted, single-color LED. Green indicates DC power ON. Off indicates an output fault |
Output Test Points | Two “banana jack” type test sockets provided on the front panel, color coded red and black. Allows operator to verify output voltage |
MECHANICAL | |
(Refer to JE Outline Configuration Dwg, P/N 03606-000.) | |
Mounting Orientation | Designed for horizontal insertion into a TEES specified Power Distribution Assembly (PDA) # 2L, 3L or 4L |
Weight | 1.36Kg [3.00 lbs] |
Retaining Fastener | Operator accessible, 8-32 UNC threaded stud and wing nut provided on the rear panel |
OPERATING ENVIRONMENT | |
Operating Temperature | -34.6º – +165.2ºF (-37.0º – +74.0ºC) ambient at full load |
Cooling | Convection only |
Relative Humidity | Up to 95% RH, non-condensing |
Operational Vibration | 0.75G peak, 5 – 500Hz along three orthogonal axis |
Storage Temperature | -40º to +185ºF (-40º to +85ºC) |
Altitude | Operating to 10,000 ft. Storage to 30,000 ft. |
MTBF | Designed for 150,000 hrs at 25°C |
INTERCONNECT | |
Input/ Output Connector | 6-circuit (2x3) panel-to-panel plug with 0.250”[6.35mm]x0.055”[1.40mm] blade type contact terminals, rated 15A/pin. General purpose black phenolic insulator material. Secured in the unit rear panel. Cinch model P-2406H-SB. Mates with Cinch model S-2406-SB or equivalent |
Note: Use of the specified mating connector is required to insure proper current capacity | |
Pin # | Function |
7 | +V1 (+24VDC) Output |
8 | DC Ground |
9 | Earth Ground |
10 | No Connection |
11 | N – Neutral (ACC) Input |
12 | L – Line (AC) Input |
Note: Pin number assignments per CalTrans spec TEES 2009, based on the connector manufacturers pin identification method | |
SAFETY, REGULATORY AND EMC | |
Designed to comply with the relevant industry standards of the authorities having jurisdiction, typically UL 60950-1, CSA 22.2 and IEC 60950 | |
EMI Filtering | Meets CISPR22B Level B, EN55022 Level B, and FCC Part 15, Level B, for conducted emissions |
Immunity | EN 61000-4-2 Level 4, ESD 8kV direct, 15kV air discharge; EN 61000-4-3 Level 3, radiated EMI field; EN 61000-4-4 Level 3, EFT/B; EN 61000-4-5 Level 3, differential / common mode voltage surge; EN 61000-4-6 Level 3, conducted susceptibility |
Harmonics | Meets EN 61000-3 (harmonics and voltage fluctuations) |
Touch Current | 1.2mA max @ 50/60Hz, 264V AC per UL 60950 test procedures (Sec. 5.0) |
Routine Factory Tests | Di-electric strength (hi-pot) to 2121V DC input- to-chassis and input-to-outputs; MegOhm to 500V output-to-chassis |